Certification
Green Certified Product Detail

NGBS point-worthy green home building products for NGBS Green Certification.

Panasonic Exhaust Ventilation Fan; Whisper FITEZDC FV-0511VFL1K, FV-0511VFL1, FV-0511VF1

Product Information

WhisperFit® DC Fan / Dimmable LED with Adjustable Color Temperature is an ideal retrofit solution. Built-in energy efficient ECM (DC) motor with Pick-A-Flow™ airflow selector allows you to select required airflow (50, 80 or 110 CFM). Single-hinged Flex-Z Fast® bracket, pre-installed alignment guides, and temporary clip allow for flexible, fast and easy installation. WhisperFit® DC low-profile housing design fits in 2 x 6 construction with 4" duct with 3" duct adapter included.

Certifications

 
  • Enegy Star
 
  • Wellness is good
NGBS 2015
Practice # Practice Points Available Additional Conditions of Use to Earn Points
902.1.4(1) Exhaust fans are ENERGY STAR®, as applicable. 2 None. 2 points per fan.

Whisper FitEZDC are ENERGY STAR certified exhaust fans.

Manufacturer’s Comments
902.1.4(2) ENERGY STAR or equivalent fans operating at or below 1 sone are installed. 3 points awarded per fan; 12 points max. 3 None. 3 points per fan.

Whisper FitEZDC are ENERGY STAR certified and operate under one sone.

Manufacturer’s Comments
902.2.1 Whole building ventilation systems is implemented per Appendix B. 3-6 System is implemented in accordance with Appendix B. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. 3 points for exhaust or supply fans; 6 points for balanced system. Mandatory when maximum air infiltration is less than 5ACH50.

Whisper FITEZDC is ready for continuous operation.

Manufacturer’s Comments
NGBS 2020
Practice # Practice Points Available Additional Conditions of Use to Earn Points
13.107.7 Exhaust systems are in accordance with Chapter 5 of the ICC IMC or ASHRAE 62.1. Mandatory. Mandatory System is installed in non-residential space.

Whisper FITEZDC features a setting timer that is in accordance with ASHRAE 62.1.

Manufacturer’s Comments
13.107.8.1 Ventilation is provided to non-residential spaces in accordance with Chapter 4 of the ICC IMC or ASHRAE 62.1. Mandatory. Mandatory System is installed in non-residential space.

Whisper FITEZDC features a setting timer that is in accordance with ASHRAE 62.1.

Manufacturer’s Comments
902.1.4(1) ENERGY STAR or equivalent fans are installed. 2 points awarded per fan; 12 points max. 2 None. 2 points per fan.

Whisper FitEZDC are ENERGY STAR certified exhaust fans.

Manufacturer’s Comments
902.1.4(2) ENERGY STAR or equivalent fans operating at or below 1 sone are installed. 3 points awarded per fan; 12 points max. 3 None. 3 points per fan.

Whisper FitEZDC are ENERGY STAR certified and operate under one sone.

Manufacturer’s Comments
902.1.6 Ventilation systems are implemented in accordance with the specifications of ASHRAE 62.1. An explanation of the operation and importance of the ventilation system is building owner manual. 3 points available. 3 System is installed in multifamily common areas. System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals.

Whisper FITEZDC meets ASHRAE 62.2.

Manufacturer’s Comments
902.2.1(1) Balanced exhaust and supply fans are installed in accordance with manufacturer’s guidelines. An explanation of the operation and importance of the ventilation system is included in the homeowner or building owner manual. 6 points available. 3 System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. Labels are appropriately labeled. Mandatory when maximum air infiltration is less than 5ACH50.

Whisper FITEZDC is ready for continuous operation.

Manufacturer’s Comments
902.2.1(2) Balanced exhaust and supply fans with supply intakes located in accordance with the manufacturer’s guidelines are installed. The operation and importance of the ventilation system is included in the homeowner or building owner manual. 6 points available. 6 System is implemented in accordance with ASHRAE 62.2-2010 Section 4. An explanation of the operation and importance of the ventilation system is included in the operation or homeowner manuals. Fans are positioned to not introduce polluted air back into the building.

Whisper FITEZDC is designed to be part of a whole-building balanced ventilation system.

Manufacturer’s Comments